BY20 Type Surge Protective Device
| Offer Type: |
|
|---|---|
| Offer Post Time: | 2009-08-25 |
| Expiration Date: | 2010-05-08 |
| Details: |
BY20 type surge protective device (short name "SPD") is suitable for AC 50/60 Hz, 380V and the following electric power systems, such as TT, IT, TN-S, TN-C, TN-C-S. It protects the electric network shocked by the thunder or over voltage.
Working condition: 1. Height: Not more than 2000m 2. Operating temperature: Normal -5~+40ºC Enlarge range: -40~+80ºC 3. Relative humidity: On condition that room temperature 30%~90% 4. Installed at no notability shocked and virated place 5. Don't be contained in explosion medium, the medium such as air and dust (including conductive dust ) shouldn't come to the degree that can corrode metal or damage insulation. Tripping device There's tripping device designed on the modular of the protector. When the protector is over heat or shocked, the tripping device can automatically separate it from the electric net, at the same time showing the indication signal. It's green when the protector is normal, red when tripping. Remote signaling contact The products can be produced available with the accessory of remote signaling contact. If one or more of modular of the protector is in malfuction, the contact will be closed, and sending the malfunction signal. Principal parameters Maximum continuous operating voltage: Uc 275 440 V~ Test grade: II Voltage protect level: Up¡Ü 1.2 1.8 2.0 kV Maximum discharge current: (8/20¦ÌS) Imax 12 15 40 62kV Nominal discharge currrent: (8/20¦ÌS) In 8 5 15 30kA Remote communication terminal parameter Type of remote communication terminal Active Terminal normal power UN/IN AC: 250V/0.5A DC: 250V/0.1A, 125V/0.2A, 75V/0.5A Conductor section Maximum single line: 1.5mm2 Main Structure and Operating Principle In three-phase four- line system, three phase lines and one zero line are connected protective device to the earth cable. (figure 1 ). In normal situation, the protective device is high resistance, when the over voltage brings for electric network shocked by thunder or other reasons, the protective device will rapidly transmit in ns, then lead the voltage into earth and protect the electric equipment. As the surge voltage through the protective device and after disappear it will recover to high resistance and not influence the normal operating. 1. There's no need to adjust the protector after installation. 2. The protector can automatically protect the electric net should it's installed rightly. 3. When operating, check whether the modular scutcheon is red, at the same time check whether the indication red light is lighting, then can change the malfunction device. |
Most Popular
-

Miniature Circuit Breaker Number of poles: 1P, 1P+N, 2P, 3P, 3P+N, and ... -

C45N Mini Circuit Breaker C45 Mini Circuit Breaker -

Magnetic Lock, Electric Door Strikes There are various magnetic locks, such as EML818, ...
-

CABS D Series Moulded Case Circuit Breaker (Mccb) CABS D Series moulded case circuit breaker ( Mccb ... -

High Breaking Capacity 10KA MCB (CYK13) CE, ROSH approval certificate, 10KA ... -

Miniature Circuit Breakers Number of Poles 1P, 1P+N, 2P, 3P, 3P+N, 4P ...
-

GFCI Receptacle (TGS-1) Current: 20A Voltage: 125V AC Frequency: ... -

BH-P Series Circuit Breaker BH-P series miniature circuit breaker is ... -

Indoor AC HV Vacuum Circuit Breaker (ZN28BI-12) General: This kind of product is indoor ...
-

Loadbreak Switch 24KV The LBS covered by this list are designed for the ... -

Surge Protector (BYX-JZ) Surge Protector / Surge Arrestor / Surge ... -

X Pole X Pole The pole tube diameter is 45mm. Design ...
-

Circuit Breaker (L-AAMN5-30) for Equipment L-AAMN5-30 is a new generation of mini type ... -

Circuit Breaker circuit breaker We were once the famous brand ... -

Fuse Handle (CT-PHP00-3) Fuse Handle for NH00-3 Fuse.
Related Searches |
Inquiry Basket (